Add to Cart
Amaxpower battery Gel solar deep cycle sealed lead acid battery (2V 1500Ah)
China Factory OEM Industry battery 2V 800ah/1000ah/1200ah/1500ah/2000ah/25000ah/3000ah Deep Cycle Gel Battery for Solar
AMaxpower deep cycle GEL battery is designed for frequent cyclic charge and discharge applications under extreme environments. By combining the newly developed Nano Silicone Gel electrolyte with high density paste, the Solar range offers high recharge efficiency at very low charge current. The acid stratification is highly reduced by adding Nano Silicone Gel.
CL Sereis 2V Long Life Deep Cycle Gel Battery
Certificates: ISO9001/14001/18001 ; CE/IEC 60896-21/22 / IEC 61427 Approved
1.Low Self Discharge For Lead Acid Battery
2.Heavy Duty Grids For Sealed AGM Battery
3.Maintenance-Free Operation For VRLA battery
Application For Industry Battery 2V:
Industry use, Communication equipment, Telecommunication control equipment; Emergency systems; Electric power systems; Golf carts; Caravan; Power station; Nuclear power station; Solar power and wind power systems; Load leveling and storage equipment; Marine equipment; Power generation plants; Alarm systems, UPS and inverters; Medical equipment; Fire and security systems, Control equipment; Stand-by electric power.
Specification
Nominal Voltage | 2V (Single cells) | |
Nominal Capacity | 1500Ah@10 hour-rate | |
Dimension | Length | 401±2(15.8 inches) |
Width | 351±2(13.8 inches) | |
Height | 344±2(13.5 inches) | |
Total Height | 369±2(14.50 inches) | |
Weight | Approx. 100kg (220.5lbs) | |
Reference Capacity (25°C/77°F ) | 20 hour rate (78.8A) | 1575Ah |
10 hour rate (150A) | 1500Ah | |
5 hour rate (270A) | 1350Ah | |
3 hour rate (400A) | 1200Ah | |
1 hour rate (975A) | 975Ah | |
Max. Discharge Current (25°C/77°F) | 5250A (5S) | |
Internal Resistance | Full charged at 25℃(77°F): Approx. 0.3mΩ | |
Charge (Constant Voltage) (25°C/77°F) |
Cycle Use |
Voltage: 2.33-2.37V@25℃(77°F) Initial Charging Current: Less than 300A |
Float Use | Voltage: 2.24-2.28V@25℃(77°F) | |
Operating Temperature Range | Discharge | -20~60°C |
Charge | -10~60°C | |
Storage | -20~60°C | |
Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
Capacity affected by Temperature (20 hour rate) |
40°C(104°F) | 102% |
25°C(77°F) | 100% | |
0°C(32°F) | 85% | |
-15°C(5°F) | 65% | |
Self-Discharge (25°C/77°F) | After 3 month | 91% |
After 6 month | 82% | |
After 12 month | 64% | |
Container Material | ABS Plastic |
Industry use, Communication equipment, Telecommunication control equipment; Emergency systems; Electric power systems; Golf carts; Caravan; Power station; Nuclear power station; Solar power and wind power systems; Load leveling and storage equipment; Marine equipment; Power generation plants; Alarm systems, UPS and inverters; Medical equipment; Fire and security systems, Control equipment; Stand-by electric power.